Product Safety Recalls

Product Recall Tracker

Fresenius Medical Care Holdings, Inc. Recall 87659

Description: AquaBplus and AquaBplus B2 Water Purification System - Product Usage: Intended for use with a hemodialysis system to remove organic and inorganic substances and microbial contaminants from the water used for hemodialysis or related therapies. Fresenius P/N 24-2500-0 All 3 units make up the AquaBplus 2500Fresenius Part Number: G02040109-US AquaBplus 3000 - Typ USA G02040115-US AquaBplus 2500 - Typ USA G02040120FMC-US AquaBplus HF- Typ USA

Fresenius Medical Care Holdings, Inc. Recall 87659 Information

StatusOngoing
Mandated?Voluntary: Firm initiated
Recall NumberZ-1536-2021
Event ID87659
Event DescriptionAquaBplus and AquaBplus B2 Water Purification System - Product Usage: Intended for use with a hemodialysis system to remove organic and inorganic substances and microbial contaminants from the water used for hemodialysis or related therapies. Fresenius P/N 24-2500-0 All 3 units make up the AquaBplus 2500Fresenius Part Number: G02040109-US AquaBplus 3000 - Typ USA G02040115-US AquaBplus 2500 - Typ USA G02040120FMC-US AquaBplus HF- Typ USA
Product TypeDevices
DistributionUS Nationwide distribution in the states of FL, MA, MD, MI, MO, NC, NJ, NY, PA, PR, SC, TN, TX.
Quantity27 units
Recall ReasonAquaBplus HF module on the AquaBplus 2500 osmosis system, an error in the US Installation Guideline instructed that 3-ring mains, instead of 2-ring mains, may be installed in combination with an AquaBplus 2500 device. The 3-ring main and fluid fly loops the heat disinfection may not be as effective as a 2-ring main installation
Device Classification20210519
Device Code InfoSerial number first stage (AquaBplus): 5BPS0601 6BPS0933 7BPS1457 7BPS1526 7BPS1458 7BPS1527 8BPS1801 8BPS1800 8BPS1870 8BPS1883 8BPS1898 8BPS1885 8BPS1884 8BPS1918 7BPS14443 8BPS1930 8BPS1928 8BPS1929 8BPS1937 8BPS1927 8BPS2052 8BPS2081 8BPS2108 8BPS2157 9BPS2234 7BPS1441 9BPS2512. Serial number second ¿stage(B2): 5BDS0194 6BDS067 7BDS0692 7BDS0726 7BDS0643 7BDS0722 8BDS0907 8BDS0909 8BDS0958 8BDS0960 8BDS0964 8BDS0963 8BDS0965 8BDS0978 7BDS0684 8BDS0989 8BDS0997 8BDS0995 8BDS0998 8BDS0992 8BDS1075 8BDS1087 8BDS1102 8BDS1139 9BDS1181 7BDS0683 9BDS1373. Serial number HF option: 5BFS0125 6BFS0241 7BFS0413 7BFS0456 7BFS0446 7BFS0486 8BFS0541 8BFS0609 8BFS0644 8BFS0665 8BFS0663 8BFS0577 8BFS0621 8BFS0616 7BFS0439 8BFS0686 8BFS0702 8BFS0703 8BFS0695 8BFS0676 8BFS0727 8BFS0757 8BFS0776 8BFS0805 9BFS0845 7BFS0477 9BFS0997
Center Classification Date20210507
Recall Initiation Date20210318
Recalling FirmFresenius Medical Care Holdings, Inc.
Initial Notification Letter
Similar To

© 2022 Recall.Report / Contact / Privacy Policy

This site's data is aggregated programmatically and provided "as is" without any representations or warranties, express or implied.
Recall.report is not affiliated with the Consumer Product Safety Commision, FDA, or US government in any way.