Full Vision Inc Recall 90995
Description: FULL VISION INC. TRACKMASTER, TREADMILL TMX428CP 220V, Model #317-07929
Full Vision Inc Recall 90995 Information
Status | Ongoing |
Mandated? | Voluntary: Firm initiated |
Recall Number | Z-0367-2023 |
Event ID | 90995 |
Event Description | FULL VISION INC. TRACKMASTER, TREADMILL TMX428CP 220V, Model #317-07929 |
Product Type | Devices |
Distribution | Wi, GA, NY, Mexico |
Quantity | 3 units |
Recall Reason | This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop. |
Device Classification | 20221214 |
Device Code Info | UDI/DI 00860176000637, Serial Numbers: FVDC-7641, FVDC-7642, FVDC-7643 |
Center Classification Date | 20221202 |
Recall Initiation Date | 20220831 |
Recalling Firm | Full Vision Inc |
Initial Notification | Letter |
Similar To |