Product Safety Recalls

Product Recall Tracker

Full Vision Inc Recall 90995

Description: FULL VISION INC. TRACKMASTER, TREADMILL TMX428CP 220V, Model #317-07929

Full Vision Inc Recall 90995 Information

StatusOngoing
Mandated?Voluntary: Firm initiated
Recall NumberZ-0367-2023
Event ID90995
Event DescriptionFULL VISION INC. TRACKMASTER, TREADMILL TMX428CP 220V, Model #317-07929
Product TypeDevices
DistributionWi, GA, NY, Mexico
Quantity3 units
Recall ReasonThis has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.
Device Classification20221214
Device Code InfoUDI/DI 00860176000637, Serial Numbers: FVDC-7641, FVDC-7642, FVDC-7643
Center Classification Date20221202
Recall Initiation Date20220831
Recalling FirmFull Vision Inc
Initial Notification Letter
Similar To

© 2022 Recall.Report / Contact / Privacy Policy

This site's data is aggregated programmatically and provided "as is" without any representations or warranties, express or implied.
Recall.report is not affiliated with the Consumer Product Safety Commision, FDA, or US government in any way.