Product Safety Recalls

Product Recall Tracker

PACIFIC LASERTECH, LLC Recall 95290

Description: N-LHP-928, HeNe Laser System, 35 mW

PACIFIC LASERTECH, LLC Recall 95290 Information

StatusOngoing
Mandated?FDA Mandated
Recall NumberZ-2977-2024
Event ID95290
Event DescriptionN-LHP-928, HeNe Laser System, 35 mW
Product TypeDevices
DistributionUS Nationwide Distribution
Quantity32
Recall ReasonThese laser products fail to comply with 21 CFR 1040.10(f)(4) Key control which requires, Each laser system classified as a Class IIIb or IV laser product shall incorporate a key-actuated master control. The key shall be removable and the laser shall not be operable when the key is removed. , because while the laser is switched on, the key can be removed from the key switch. The correction is replacement with a key switch that captures the key when in the on position.
Device Classification20240918
Device Code InfoN-LHP-928
Center Classification Date20240910
Recall Initiation Date20240301
Recalling FirmPACIFIC LASERTECH, LLC
Initial Notification Letter
Similar To

© 2022 Recall.Report / Contact / Privacy Policy

This site's data is aggregated programmatically and provided "as is" without any representations or warranties, express or implied.